Removal
System Cover
Identify the system cover highlighted in blue.
Using a flat head or a Phillips screwdriver, rotate the lock counter clockwise.
Lift the latch till the system cover slides back.
Hold the cover on both sides, and lift the cover away from the system.
Butterfly riser
Identify the butterfly riser assembly highlighted in blue
Loosen the captive screw that secures the riser to the system
Hold the touch points, and lift the expansion card riser, from the riser connector, on the system board.
Air shroud
Identify the air shroud highlighted in blue
Holding the touch points, lift the cooling shroud away from the system.
Internal PERC riser
Identify the internal PERC riser highlighted in blue.
Open the cable guiding latch for easy access.
Lower the plunger.
Hold the blue touch points and lift the internal PERC riser out of the system.
Turn the internal riser so that the PERC card is facing up.
Press the cable connector and disconnect the cable connected to the internal PERC card.
Control panel -Left
Identify the control panel highlighted in blue
Disconnect the control panel cable from the system board connector.
Unoute the control panel cable from the side wall of the system.
Remove the screws which secure the left control panel assembly to the system
Remove the left control panel assembly away from the system.
Install
Control panel -Left
Identify the control panel location highlighted in blue
Route the control panel cable through the side wall of the system.
Align the left control panel assembly with the slot and slide into place
Connect the control panel cable to the system board connector and secure it using cable latch
Install the screws that secure the control panel assembly to the system
Internal PERC riser
Identify the internal PERC riser location highlighted in blue.
Connect the cable to the internal PERC card.
Holding the blue touch points, align the slot on the internal PERC riser to the guide on the system board.
Insert the internal riser card’s edge connector firmly into the system board connector until the riser is fully seated.
Lift the plunger to lock the riser in place.
Close the cable guiding latch.
Air shroud
Identify the cooling shroud location highlighted in blue
Align the tabs on the air shroud with the slots on the system.
Lower the air shroud into the system until it is firmly seated.
StepInfoTxt
Butterfly riser
Identify the butterfly riser assembly location highlighted in blue
Lower the expansion card riser into place until the expansion card riser connector is fully seated in the connector.
Tighten the captive screw that secures the riser to the system
System Cover
Identify the system cover location highlighted in blue.
Align the tabs on the system cover with the guide slots on the system.
Push the system cover latch down.
Using a flat head or Phillips screwdriver, rotate the lock clockwise.
StepInfoTxt